Are you stuck in the minefield of public health-tech procurement?
If you are (or about to start) selling into the NHS you will no doubt come across a four-letter acronym called DTAC.
The Digital Technology Assessment Criteria (DTAC) is not a piece of over-complicated governance but is how the NHS achieves the safety, security, and effectiveness of any new digital technologies. In your case, it is an opportunity to demonstrate the credibility of your product and its readiness to one of the largest health systems in the world.
The Five Pillars of DTAC: Not a Tick-Box Only Exercise.
There are five areas on which DTAC is established. You must be strong in all of them, just like a chain the tech is only as strong as it’s weakest link.
- Clinical Safety: This pillar is everything to demonstrate that you have identified and eliminated any risks your product may have for a patient or a clinician systematically. It is not being 100% risk-free, but demonstrating that you are in control of the risks.
- Data Protection: The NHS deals with highly sensitive personal data. This pillar ensures that you are a responsible custodian of that information. You will be required to show that you are in accordance with the UK data protection law (UK GDPR and the Data Protection Act 2018), that you have a defined legal purpose of processing data and that you are open about how you use the data.
- Technical Security: What are you doing to ensure that the data is not stolen by hackers? Questions concerning your cloud security, encryption, vulnerability management, and your incident response plan in the case of a breach are to be expected.
- Interoperability: Your product can not be an island. It must communicate with other systems in the NHS. This pillar evaluates the ability of your technology to integrate with your important NHS IT infrastructure, such as the NHS App, electronic patient records (EPRs), and other clinical systems. .
- Usability & Accessibility: Your design should be intuitive, and accessible to people with additional accessibility requirements. Consider looking into and achieving the WCAG standards
DTAC, DCB and the Clinical Safety Officer
Clinical Risk Management is regulated by two clinical safety standards which apply across England, Wales & Northern Ireland.
DCB0129 (Clinical Risk Management: Application Design): This standard is used by health IT system manufacturers. It requires safety to be built into their products from the very beginning, a specified process, and a Clinical Safety Case Report and Hazard Log to demonstrate that every sensible measure has been taken to reduce risk.
DCB0160 (Clinical Risk Management: Deployment and Use): This standard is relevant to health care organisations using such systems. It involves the management of the clinical risks related to their deployment, configuration, and usage in their particular environment.
These frameworks provide a unified language and methodology, ensuring alignment between those who create and those who use digital health solutions in their efforts to ensure patient safety.
As a manufacturer you MUST have a hazard log and Clinical Safety Case Report, produced by a qualified Clinical Safety Officer (CSO) to achieve DCB 0129 & DTAC compliance.
Your Game Plan to DTAC Success.
Feeling overwhelmed? Don’t be. Tackle it step-by-step.
- Start Early, Not at the Finishing Line: Do not take DTAC as a last-minute paperwork. Motivate it into your product growth cycle at the outset. Your Hazard Log must be a dynamic document as the features are added.
- Hire a Clinical Safety Officer (CSO): You cannot do without one. Their clinical acumen is an invaluable way to identify the risks that would have gone unnoticed by a non-clinician, and required to achieve DCB 0129 compliance
- Understand the Five Pillars: Identify your strengths and weaknesses, and start to compile your evidence early.
- Be Proactive with Interoperability & Cyber Security: . Does your product operate in isolation, or require data import and export to electronic patient records, LIMS, EPMRs and PAC systems? Does it link into the NHS. Address? Describing how you securely store, send and recieve data is essential for successful DTAC compliance.
- Test Usability on Real Users: Move beyond your insiders. Carry out usability tests on a representative sample of the prospective users, including the disabled. This feedback is gold for your product enhancement, and this will give you solid evidence for your DTAC submission.
The Bottom Line: How DTAC Affects Procurement.
Achieving DTAC compliance is a precondition for any NHS procurement. It is what gets you a seat at the table.
The DTAC scorecard helps NHS buyers to screen out products that do not fit the necessary safety and security requirements in a matter of seconds. A good DTAC submission, where there is a good clinical safety case, does two things:
- It de-risks the purchase for the NHS, and makes them trust your product.
- It distinguishes you among other competitors who might have the flashy product and poor safety platforms.
In the digital health world full of competition, a good DTAC submission is not merely a compliance issue, but your strategic edge. It demonstrates to the NHS that you are not simply a technological firm, but a responsible collaborator in the provision of effective and safe patient care.
Ready to build your safety case? The full DTAC documentation and resources are available on the NHS England website to guide your journey.